Lightning Management Across a Wind Farm
Lightning is a leading cause of unplanned blade repair, but operators rarely know which turbines have been struck or how well remote detection reflects events at the tower. This case study reports one lightning season of on-tower strike monitoring across more than 100 turbines at a single site. The analysed event records span October 2025 to May 2026. The sensors recorded 330 confirmed strike events, 292 of them assigned to 16 storms, and 91% of the monitored turbines were struck at least once. The events were cross-checked against two commercial lightning location service networks. Network A matched 84% of the 292 events it could be assessed against, and Network B 79% of the full 330. The article characterises the season’s strike population, quantifies how closely each network agrees with the on-tower turbine sensor, and reports the 16 turbines with new blade damage found in the 2026 inspection, which could all be traced to confirmed strikes.

By Elizabeth Beavis, Tilt Renewables, Rosemary Barnes, Pardalote Consulting, and Matthew Stead, eologix-ping, Australia