Woelfel Figure 1Load Monitoring and Lifetime Assessment of Wind Turbine Structures
 
A wind turbine is one of the industrial structures with the highest vibration loads within its lifetime. It has to withstand up to 250 million load cycles within approximately 20 years. The vibration loads of wind turbines vary considerably depending on the location and operational mode of the wind turbine. Even two wind turbines in the same wind farm may differ significantly in their vibration loads. In the design phase, these loads can only roughly be determined, leading to potential reserves of a turbine’s lifetime during operation. Therefore, the structural monitoring of turbine towers is an essential part of controlling the lifetime of a wind turbine. In current operations on-site, the use of the retrofit solution SHM.Tower reveals that considerable reserves exist, allowing lifetime extension of turbine towers. Furthermore, lifetime-driven operation of wind turbines can be realised by using SHM.Tower, which is energy self-sufficient.
 
By Dr.-Ing. Carsten Ebert, Dr.-Ing. Manuel Eckstein, Dr.-Ing. Georg C Enss and Dipl.-Ing. Bernd Wölfel, Wölfel Wind Systems, Germany

Login

Use of cookies

Windtech International wants to make your visit to our website as pleasant as possible. That is why we place cookies on your computer that remember your preferences. With anonymous information about your site use you also help us to improve the website. Of course we will ask for your permission first. Click Accept to use all functions of the Windtech International website.